E7-Feeder

Motor protection

E7-Feeder

Motor protection

E7-Feeder

Motor protection

E7-Feeder

Motor protection

Overview

The E7-Feeder is a dedicated motor protection and control IED; it is member of the DTIVA product type in the EuroProt+ product family.
The DTIVA products are configured to protect, control and supervise elements of the utility and industrial distribution systems. Because of the modular architecture, the modules are assembled and configured according to the user’s requirements; from that point on, the software determines the functions.

The EuroCAP configuration tool, which is available free of charge, offers a user-friendly and flexible application for protection, control and measurement functions to ensure that the IED-EP+ devices are fully customisable.






General features

  • Native IEC 61850 IED with Edition 2 compatibility
  • Scalable hardware to adapt to different applications
  • 84 HP or 42HP wide rack size (height: 3U)
  • The pre-defined factory configuration can be customized to the user’s specification with the powerful EuroCAP tool
  • Flexible protection and control functionality to meet special customer requirements
  • Advanced HMI functionality via color touchscreen and embedded WEB server, extended measuring, control and monitoring functions
  • User configurable LCD user screens, which can display SLDs (Single Line Diagrams) with switchgear position indication and control as well as measuring values and several types of controllable objects.
  • Various protection setting groups available
  • Enhanced breaker monitoring and control
  • High capacity disturbance recorder (DRE) and event logging:
    • DRE for up to 32 analogue and 64 digital signal channels.
    • Event recorder can store more than 10,000 events.
  • Several mounting methods: Rack; Flush mounting; Semi-flush mounting; Wall mounting; Wall-mounting with terminals; Flush mounting with IP54 rated cover.
  • Wide range of communication protocols:
    • Ethernet-based communication: IEC61850; IEC60870-5-104; DNP3.0 TCP; Modbus TCP
    • Serial communication: DNP3.0; IEC60870-5-101/103; MODBUS, SPA
  • The EuroProt+ family can handle several communication protocols simultaneously.
  • Built-in self-monitoring to detect internal hardware or software errors
  • Different time sources available: NTP server; Minute pulse; Legacy protocol master; IRIG-B000 or IRIG-B12X

 

Application

The E7-Feeder configuration is designed to protect, control and supervise medium- to large-sized three-phase motors in the manufacturing and processing industries. The IED provides a wide range of protection functions, which are based on current, voltage and temperature measurements: non-directional overcurrent, directional earth fault protection, various voltage protection functions (over-/undervoltage, negative, positive sequence, residual voltage protection),
In addition to these basic functions, the relay provides a number of other special motor protection and supervision functions that enable it to protect and run the motor more effectively and safely: motor thermal protection, motor startup supervision, asymmetry protection, loss of load protection, prolonged start locked rotor protection.
The motor differential protection function is available as an option in the E7-Feeder relay.
The relay can record the starting current, which is most helpful in analysing motor performance during the critical start-up period.
Furthermore, the relay offers control, measuring and monitoring functions; consequently, the IED can be used as a bay control device.

Scope of application

  • Protect motors in industrial networks and power plants
  • Protection against thermal overload of the stator and rotor
  • Monitoring the thermal state of the motor by motor thermal replica function
  • Voltage transformer supervision
  • Phase reversal protection with negative sequence overvoltage protection
  • Motor start-up supervision
  • Overload detection while in use
  • Temperature monitoring via temperature sensors with RTD module
  • Loss-of-load (undercurrent) protection
  • Protection against instability due to undervoltage
  • Differential protection for internal phase-to-phase or phase-to-ground faults
  • Back-up protection unit application

 

Protection & control functions

The E7-Feeder configuration is designed to protect large motors on the medium-voltage network. It measures three phase currents, the residual current and, additionally, three phase voltages and the residual voltage. These measurements facilitate the operation of current- and voltage-based functions.
In addition to the usual overcurrent and overvoltage functions, this configuration includes special motor protection functions such as a dedicated thermal replica function for motors, negative sequence overcurrent protection function, asymmetry protection, loss of load protection, motor startup supervision. Alternatively, the E7-Feeder unit may be applied as a differential protection together with the optional motor differential protection.

Protection & control functions IEC ANSI *Inst.
Overexcitation protection function V/Hz 24 1 20/12/2024
Definite time undervoltage protection function U<, U<< 27 2 19/12/2024
Loss-of-load (undercurrent) protection function I< 37 1 20/08/2025
GGIORTD temperature measurement function 38/49T op. 27/11/2024
Negative sequence overcurrent protection function I2> 46 1 04/04/2025
Negative sequence definite time overvoltage protection function U2 > 47 1 10/10/2024
Motor startup supervision function Istart/I(t) 48/66 1 08/03/2022
Motor thermal protection function T> 49M 1 11/07/2022
Three-phase instantaneous overcurrent protection function I >>> 50 1 17/01/2025
Residual instantaneous overcurrent protection function Io>>> 50N/50G 1 09/12/2025
Breaker failure protection functions CBFP 50BF 1 03/10/2022
Three-phase time overcurrent protection function I>, I>> 51 2 04/04/2025
Residual overcurrent protection function Io>, Io>> 51N/51G 2 04/04/2025
Definite time overvoltage protection function U>, U>> 59 2 19/12/2024
Residual definite time overvoltage protection function Uo>, Uo>> 59N 2 20/12/2024
Voltage transformer supervision and dead line detection function 60 1 09/07/2019
Current unbalance function (CT Supervision) 60 1 20/12/2024
Directional residual time overcurrent protection function Io Dir>, Io Dir>> 67N/67G 2 03/12/2025
Inrush current detection function I2h> 68 1 20/12/2024
Generator differential protection function 3IdG > 87G/87M op. 09/07/2019
*The INST. column contains the numbers of the pre-configured function blocks in the factory configuration.These numbers may be different in order to meet the user’s requirements.

Documentation

Product Configuration Options
IEC61850 documents
TISSUEs Implementation Conformance Statement (TICS) for the IEC 61850 Edition 2 server interface in Europrot+ product family 18/04/2023
Protocol Implementation eXtra Information for Testing (PIXIT) for the IEC 61850 Edition 2 server interface in Europrot+ product family 18/04/2023
Protocol Implementation Conformance Statement (PICS) for the IEC 61850 Edition 2 server interface in Europrot+ product family 18/04/2023
Model Implementation Conformance Statement (MICS) for the IEC 61850 Edition 2 server interface in DTIVA product 18/04/2023
Protocol Implementation Conformance Statement (PICS) for the IEC 61850 Edition 1 server interface in Eurorot+ product family 09/07/2019
Protocol Implementation eXtra Information for Testing (PIXIT) for the IEC 61850 Edition 1 server interface in Europrot+ product family 09/07/2019
Model Implementation Conformance Statement (MICS) for the IEC 61850 Edition 1 server interface in the Eurorot+ product family 09/07/2019
Type description
Distributed network components protection & control 18/07/2025
Hardware Guides
Hardware description 05/05/2025
Maintenance guide 28/06/2023
Application Guides
Operating Manual and Troubleshooting Guide - system version: 2.8 02/10/2023
Configuration Descriptions
E7-Feeder configuration description 11/03/2020
E7-Feeder_H product configuration options 11/05/2026
E7-Feeder_F product configuration options 23/03/2026

Order

E7-FEEDER_H: 42hp_35_rj_on_order_line.jpg

E7-FEEDER_F:

84hp_35_rj_on_edited_order_line_2.jpg
Protecta products can be ordered by using an Order Code. This code specifies the hardware and the configuration.
Please always refer to a valid Order Code when placing an order.
The Order Code page can be opened by clicking the link below.