The S24 Variant 3 is used mostly as the main or backup protection of overhead lines or cable feeders in distribution networks. The main protection function of this configuration is the distance protection function.
It is a member of the S24 series, which is part of the EuroProt+ Smart Line. Members of the Smart Line also offer a wide range of functions but they do so in a small, compact enclosure so that they can be installed in locations with limited space available for the protection equipment.
The S24 series contain special selections of the EuroProt+ modules and functions, composed with cost effectiveness in mind. Depending on the standard configuration chosen (Variant 1, Variant 2,…), the IED is adapted to the protection of medium-voltage feeders in isolated neutral, resistance earthed, compensated and solidly earthed networks. Once the application-specific settings have been defined for the standard configuration IED, it can be put into service directly. Areas of application include protection functions for a large variety of applications, e.g. transformer differential and restricted earth fault protection, frequency and voltage based protection, motor protection, thermal overload protection.
The EuroCAP configuration tool, which is available free of charge, offers a user-friendly and flexible application for protection, control and measurement functions to ensure that the IED-EP+ S24 devices are fully customisable.
General features
Native IEC 61850 IED with Edition 2 compatibility
Standard module layouts with options
24 HP wide rack size (height: 3U)
The pre-defined factory configuration can be customized to the user’s specification with the powerful EuroCAP tool
Different HMI types: advanced HMI with color touchscreen and black-and-white display with 4 tactile push buttons. An embedded web server and extended measuring, control and monitoring functions are also available for both types
User configurable LCD user screens for the HMI-type color touchscreen, which can display SLDs (Single Line Diagrams) with switchgear position indication and control as well as measuring values and several types of controllable objects
Various protection setting groups
Enhanced breaker monitoring and control
High capacity disturbance recorder (DRE) and event logging:
DRE for up to 32 analogue and 64 digital signal channels
Event recorder can store more than 10,000 events
Mounting methods: Flush mounting; Semi-flush mounting; Din rail mounting
Serial communication: DNP3.0; IEC60870-5-101/103; MODBUS, SPA
Legacy network based protocols via 100Base-FX and 10/100Base-TX (RJ45)
Optional communication ports: Fiber optical Ethernet (MM/ST, SM/FC), RJ45, Serial POF, Serial glass fiber, RS-485/422
Handling of several communication protocols simultaneously
Built-in self-monitoring to detect internal hardware or software errors
Different time sources available: NTP server; Minute pulse; Legacy protocol master
Application
Variant 3 is used mostly as the main or backup protection of overhead lines or cable feeders in distribution networks and motors. It is a member of the S24 series, which is part of the EuroProt+ Smart Line.
The main protection function of the Variant 3 relay is the 5-zone distance protection function. The configuration includes the simplified version of this function: it generates three-phase trip commands, but in the event of cross-country faults it also makes use of the phase preference logic. Additionally, Variant 3 includes a variety of versatile feeder protection functions such as three-phase, residual and negative sequence overcurrent protection, thermal overload protection, etc. The voltage measurement adds directionality extension to the configured phase and residual overcurrent function, under- and overpower functions in addition to the three-phase under- and overvoltage and residual overvoltage functions. Frequency-based functions are also available. It can be used as a back-up protection relay for downstream equipment (e.g. feeders, cables). The synchrocheck and automatic reclosing functions are also part of the standard configuration.
The IED includes a wide range of control and supervisory functions, which provide full control and user-defined interlocking schemes for the primary switchgear at the substation.
SCOPE OF APPLICATION
Distance protection function, overcurrent, directional overcurrent and thermal overload protection functions for overhead lines and cable feeders
Over- and undervoltage, residual and negative sequence overvoltage protection functions
Frequency-based functions
Over- and underpower function
The implemented protection functions provide back-up protection for downstream equipment (e.g. feeders, cables etc.)
Synchrocheck and automatic reclosing function
Breaker failure protection function
Current unbalance detection of CT’s
VT supervision function
Programmable interlocking schemes
Protection & control functions
The Variant 3 configuration measures the three phase currents, the residual current component as well as three phase voltages and the zero sequence voltage component. These measurements allow, in addition to the current- and voltage-based functions, directionality extension of the configured phase and residual overcurrent functions.
The main protection function in this application is the distance protection function. The configuration includes the simplified version of this function: it generates three-phase trip commands, but in the event of cross-country faults it also makes use of the phase preference logic. The scope of functions is supplemented with the automatic reclosing function.
Based on the voltage measurement, the frequency is also evaluated to realize frequency-based protection functions. The configuration is designed to meet the protection requirements of a medium-voltage field unit.
Protection & control functions
IEC
ANSI
*Inst.
Directional Element function (2.10 systems only)
?
?
1
11/07/2025
Distance protection for compensated or isolated networks function
Z<
21
1
09/07/2019
Switch-onto-fault preparation function
1
06/09/2024
Synchro check synchro switch function
SYNC
25
1
14/11/2024
Definite time undervoltage protection function
U<, U<<
27
2
19/12/2024
Negative sequence overcurrent protection function
I2>
46
1
04/04/2025
Broken conductor protection
I2/I1>
46BC
1
30/06/2020
Negative sequence definite time overvoltage protection function
U2 >
47
1
10/10/2024
Line thermal protection function
T >
49
1
03/01/2025
Three-phase instantaneous overcurrent protection function
I >>>
50
1
17/01/2025
Residual instantaneous overcurrent protection function
Io>>>
50N/50G
1
09/12/2025
Breaker failure protection functions
CBFP
50BF
1
03/10/2022
Three-phase time overcurrent protection function
I>, I>>
51
2
04/04/2025
Residual overcurrent protection function
Io>, Io>>
51N/51G
2
04/04/2025
Definite time overvoltage protection function
U>, U>>
59
2
19/12/2024
Residual definite time overvoltage protection function
Uo>, Uo>>
59N
2
20/12/2024
Current unbalance function (CT Supervision)
60
1
20/12/2024
Directional three-phase overcurrent protection function
I Dir>, I Dir>>
67
2
04/04/2025
Directional residual time overcurrent protection function
Io Dir>, Io Dir>>
67N/67G
2
03/12/2025
Inrush current detection function
I2h>
68
1
20/12/2024
Automatic reclosing function for medium voltage networks
0 -> 1
79
1
10/12/2024
Overfrequency protection function
f>, f>>
81O
2
20/12/2024
Underfrequency protection function
f<, f<<
81U
2
20/12/2024
Rate of change of frequency function
df/dt
81R
2
20/12/2024
*The INST. column contains the numbers of the pre-configured function blocks in the factory configuration.These numbers may be different in order to meet the user’s requirements.
Documentation
Product Configuration Options
Brochures
EuroProt+ overview
19/02/2021
System Description
IED-EP+ S24 general specification
19/02/2021
Hardware Guides
Maintenance guide
28/06/2023
Hardware description
31/07/2026
IEC61850 documents
TISSUEs Implementation Conformance Statement (TICS) for the IEC 61850 Edition 2 server interface in Europrot+ product family
18/04/2023
Protocol Implementation eXtra Information for Testing (PIXIT) for the IEC 61850 Edition 2 server interface in Europrot+ product family
18/04/2023
Protocol Implementation Conformance Statement (PICS) for the IEC 61850 Edition 2 server interface in Europrot+ product family
18/04/2023
Model Implementation Conformance Statement (MICS) for the IEC 61850 Edition 1 server interface in the Eurorot+ product family
09/07/2019
Protocol Implementation eXtra Information for Testing (PIXIT) for the IEC 61850 Edition 1 server interface in Europrot+ product family
09/07/2019
Protocol Implementation Conformance Statement (PICS) for the IEC 61850 Edition 1 server interface in Eurorot+ product family
09/07/2019
Configuration Descriptions
Variant 3 configuration description
30/05/2023
Variant 3 product configuration options
27/07/2026
Order
Protecta products can be ordered by using an Order Code. This code specifies the hardware and the configuration. Please always refer to a valid Order Code when placing an order. The Order Code page can be opened by clicking the link below.
Protecta provides own‑developed protection, automation & control devices for power generation, transmission, distribution, industrial and renewable energy (microgrid) applications.
Késmárk u. 7/A, 1158 Budapest, Hungary+36 1 415 3800protecta@protecta.huProtecta LinkedIn