Login registration
e-mail Password Forgot Your password?
Please enter the email address you provided during your previous registration, to which we will send your tasks!
full name e-mail alternate e-mail language Password confirm password company position mailing address Phone number

Variant 5

Two winding transformer differential protection

Variant 5

Two winding transformer differential protection

Variant 5

Two winding transformer differential protection

Variant 5

Two winding transformer differential protection

Protection & control functions

Protection & control functions IEC ANSI *Inst.
Differential Protection Function (versions 5 and up on 2.10 systems) 3IdT > 87T 1 18/12/2024
Negative sequence overcurrent protection function I2> 46 1 04/04/2025
Line thermal protection function T > 49 1 03/01/2025
Three-phase instantaneous overcurrent protection function I >>> 50 2 17/01/2025
Residual instantaneous overcurrent protection function Io>>> 50N/50G 2 09/12/2025
Breaker failure protection functions CBFP 50BF 2 03/10/2022
Three-phase time overcurrent protection function I>, I>> 51 2 04/04/2025
Residual overcurrent protection function Io>, Io>> 51N/51G 2 04/04/2025
Current unbalance function (CT Supervision) 60 2 20/12/2024
Inrush current detection function I2h> 68 1 20/12/2024
Generator differential protection function 3IdG > 87G/87M 1 op. 09/07/2019
*The INST. column contains the numbers of the pre-configured function blocks in the factory configuration.These numbers may be different in order to meet the user’s requirements.

Documentation

Product Configuration Options
IEC61850 documents
TISSUEs Implementation Conformance Statement (TICS) for the IEC 61850 Edition 2 server interface in Europrot+ product family 18/04/2023
Protocol Implementation eXtra Information for Testing (PIXIT) for the IEC 61850 Edition 2 server interface in Europrot+ product family 18/04/2023
Protocol Implementation Conformance Statement (PICS) for the IEC 61850 Edition 2 server interface in Europrot+ product family 18/04/2023
Protocol Implementation eXtra Information for Testing (PIXIT) for the IEC 61850 Edition 1 server interface in Europrot+ product family 09/07/2019
Protocol Implementation Conformance Statement (PICS) for the IEC 61850 Edition 1 server interface in Eurorot+ product family 09/07/2019
Model Implementation Conformance Statement (MICS) for the IEC 61850 Edition 1 server interface in the Eurorot+ product family 09/07/2019
Brochures
EuroProt+ overview 19/02/2021
System Description
IED-EP+ S24 general specification 19/02/2021
Hardware Guides
Maintenance guide 28/06/2023
Hardware description 31/07/2026
Configuration Descriptions
Variant 5 configuration description 30/05/2023
Variant 5 product configuration options 27/07/2026

Order

Protecta products can be ordered by using an Order Code. This code specifies the hardware and the configuration.
Please always refer to a valid Order Code when placing an order.
The Order Code page can be opened by clicking the link below.