Three-winding transformer differential protection and control device (with phase-voltage measurement added)
Three-winding transformer differential protection and control device (with phase-voltage measurement added)
Three-winding transformer differential protection and control device (with phase-voltage measurement added)
Three-winding transformer differential protection and control device (with phase-voltage measurement added)
The E5-TR is a dedicated three-winding transformer protection and control IED; the relay provides complex protection, control and monitoring functions for three-winding power transformers. It is member of the DTRV product type in the EuroProt+ product family.
The DTRV type is designed particularly for protection and control applications of power transformers and generators including generator-transformer blocks. Additionally, the DTRV product type includes a variety of versatile protection functions to meet the users´ most exacting requirements.
Because of the implemented control, measuring and monitoring function, the IED can also be used as a bay control unit.
The EuroCAP configuration tool, which is available free of charge, offers a user-friendly and flexible application for protection, control and measurement functions to ensure that the IED-EP+ devices are fully customisable.
The E5-TR is a dedicated three-winding transformer protection and control IED; the relay provides complex protection, control and monitoring functions for three-winding power transformers. It is member of the DTRV product type in the EuroProt+ product family.
The E5-TR relay provides a variety of versatile protection functions along with the main transformer differential protection, such as 3ph, Io and I2 overcurrent protection, overload protection, restricted earth-fault protection etc.
Sensitive restricted earth-fault protection (REF) is the final element in the overall differential protection system, which detects even single phase-to-ground faults close to the grounded neutral of the transformer.
The multiple instances of the implemented three-phase and residual overcurrent functions are provided for the segregated protection of both transformer windings.
Furthermore, several voltage-based protection functions are available for one transformer winding based on the three-phase voltage measurement. The connections of the voltage measurement depends on the current application.
The E5-TR transformer protection relay can support double-breaker terminals on any side of the transformer such as breaker and a half or ring bus topology.
Automatic phase shift and turns ratio compensation for all types of transformer winding connections.
It can be used as a back-up protection relay for downstream equipment (e.g. feeders, cables).
The IED includes a wide range of control and supervisory functions, which provide full control and user-defined interlocking schemes for the primary switchgear at the substation.
The E5-TR configuration measures three phase currents, the residual current component from both sides of a three-winding, three-phase transformer and, additionally, three phase voltages. These measurements allow, in addition to the current- and voltage-based functions, directionality extension of the residual overcurrent function.
The main protection functions are the transformer differential protection and the restricted earth-fault protection functions. Based on the voltage measurement, the frequency is also evaluated to facilitate frequency-based protection functions.
The additional protection functions can provide back-up protection relay for downstream equipment (e.g. feeders, cables etc.).

| Protection & control functions | IEC | ANSI | *Inst. | |||
|---|---|---|---|---|---|---|
| Differential Protection Function (versions 5 and up on 2.10 systems) | 3IdT > | 87T | 1 | 2024.12.18. | download | |
| Overexcitation protection function | V/Hz | 24 | 1 | 2024.12.20. | download | |
| Definite time undervoltage protection function | U<, U<< | 27 | 2 | 2024.12.19. | download | |
| Negative sequence overcurrent protection function | I2> | 46 | 1 | 2025.04.04. | download | |
| Negative sequence definite time overvoltage protection function | U2 > | 47 | 1 | 2024.10.10. | download | |
| Line thermal protection function | T > | 49 | 1 | 2025.01.03. | download | |
| Three-phase instantaneous overcurrent protection function | I >>> | 50 | 3 | 2025.01.17. | download | |
| Residual instantaneous overcurrent protection function | Io>>> | 50N/50G | 3 | 2025.12.09. | download | |
| Breaker failure protection functions | CBFP | 50BF | 3 | 2022.10.03. | download | |
| Three-phase time overcurrent protection function | I>, I>> | 51 | 3 | 2025.04.04. | download | |
| Residual overcurrent protection function | Io>, Io>> | 51N/51G | 3 | 2025.04.04. | download | |
| Definite time overvoltage protection function | U>, U>> | 59 | 2 | 2024.12.19. | download | |
| Residual definite time overvoltage protection function | Uo>, Uo>> | 59N | 2 | 2024.12.20. | download | |
| Current unbalance function (CT Supervision) | 60 | 3 | 2024.12.20. | download | ||
| Directional residual time overcurrent protection function | Io Dir>, Io Dir>> | 67N/67G | 2 | 2025.12.03. | download | |
| Overfrequency protection function | f>, f>> | 81O | 2 | 2024.12.20. | download | |
| Underfrequency protection function | f<, f<< | 81U | 2 | 2024.12.20. | download | |
| Rate of change of frequency function | df/dt | 81R | 2 | 2024.12.20. | download | |
| Restricted earth-fault protection function | REF | 87N | 3 | 2024.12.10. | download |
| IEC61850 documents | |||
|---|---|---|---|
| TISSUEs Implementation Conformance Statement (TICS) for the IEC 61850 Edition 2 server interface in Europrot+ product family | 18/04/2023 | download | |
| Protocol Implementation eXtra Information for Testing (PIXIT) for the IEC 61850 Edition 2 server interface in Europrot+ product family | 18/04/2023 | download | |
| Protocol Implementation Conformance Statement (PICS) for the IEC 61850 Edition 2 server interface in Europrot+ product family | 18/04/2023 | download | |
| Model Implementation Conformance Statement (MICS) for the IEC 61850 Edition 2 server interface in DTRV product | 18/04/2023 | download | |
| Protocol Implementation eXtra Information for Testing (PIXIT) for the IEC 61850 Edition 1 server interface in Europrot+ product family | 20/03/2017 | download | |
| Protocol Implementation Conformance Statement (PICS) for the IEC 61850 Edition 1 server interface in Eurorot+ product family | 20/03/2017 | download | |
| Model Implementation Conformance Statement (MICS) for the IEC 61850 Edition 1 server interface in the Eurorot+ product family | 21/05/2012 | download | |
| Type description | |||
| Transformer protection & control | 18/07/2025 | download | |
| Hardware Guides | |||
| Hardware description | 05/05/2025 | download | |
| Maintenance guide | 28/06/2023 | download | |
| Application Guides | |||
| Operating Manual and Troubleshooting Guide - system version: 2.8 | 19/09/2023 | download | |
| Configuration Descriptions | |||
| E5-TR configuration description | 23/05/2014 | download | |
| E5-TR_H product configuration options | 23/03/2026 | download | |
| E5-TR_F product configuration options | 23/03/2026 | download |