magyar | english || Login | registration
Downloads»EuroProt+
Documentation
Brochures Verzió Formátum Dátum Méret
EuroProt+ overview 1.0 08/04/2019 1.08 MB
Type description Verzió Formátum Dátum Méret
Busbar protection 1.0 05/04/2019 1.17 MB
Distributed network components protection & control 1.0 05/04/2019 2.24 MB
DVEZ - Bay control unit 1.0 19/05/2015 4.17 MB
Transformer protection & control 1.0 05/04/2019 2.08 MB
Transmission line protection & control 1.0 05/04/2019 2.09 MB
Hardware Guides Verzió Formátum Dátum Méret
Hardware description 1.40 19/10/2018 2.75 MB
Maintenance guide 1.3 19/02/2014 170.12 KB
Technical notes on EOB interoperability 1,0 27/06/2011 519.33 KB
Application Guides Verzió Formátum Dátum Méret
Application of high-speed TRIP contacts 1.1 02/10/2017 657.90 KB
EuroProt+ RS485/422 application note 1.0 29/10/2012 606.84 KB
Line differential communication application guide 1.4 29/11/2019
0.99 MB
Quick start guide 1.0 27/06/2011 944.79 KB
Remote user interface description 3.0 06/06/2019 1.18 MB
Trip Circuit Supervision (TCS) in EuroProt+ devices 1.2 09/08/2019 471.85 KB
Troubleshooting guide 1 12/04/2016 1.53 MB
IEC61850 documents Verzió Formátum Dátum Méret
Model Implementation Conformance Statement - MICS 1.0 21/05/2012 864.71 KB
Protocol Implementation Conformance Statement - PICS 1.1 20/03/2017 261.09 KB
Protocol Implementation Extra Information - PIXIT 1.1 20/03/2017 259.27 KB
Legacy protocols Verzió Formátum Dátum Méret
EP+ DNP3 Device Profile 1.0 13/12/2012 182.97 KB
IEC-60870-5-101 -104 -103 interoperability list 24/06/2011 218.62 KB
Modbus protocol description 1.0 22/11/2013 366.46 KB
Function blocks short Verzió Formátum Dátum Méret
Automatic tap-changer controller function 1.0 27/06/2011 605.02 KB
Average and maximum measurement function block description 1.0 27/09/2013 486.05 KB
Breaker failure protection function for not solidly grounded networks 1.1 21/04/2016 559.25 KB
Breaker failure protection function for solidly grounded networks 1.0 29/04/2014 214.74 KB
Capacitor overvoltage protection function 1.1 30/05/2018 941.43 KB
Capacitor unbalance protection for blocks in bridge connection 1.0 17/01/2013 699.91 KB
Capacitor unbalance protection for blocks in double star connection 1.0 17/12/2012 692.81 KB
Centralized busbar differential and breaker failure protection function 1.0 17/12/2015 767.96 KB
Circuit breaker control function block 1.0 27/07/2011 521.52 KB
Circuit breaker wear monitoring function 1.1 06/09/2016 632.56 KB
Circuit breaker wear monitoring function for railway application 1.1 06/09/2016 553.07 KB
Current input function 1.0 02/05/2012 472.74 KB
Current input function for railway application 1.0 05/06/2015 531.97 KB
Current transformer supervision function 1.0 18/07/2011 438.78 KB
Current unbalance function 1.0 27/06/2011 440.35 KB
Dead line detection function 1.0 27/06/2011 452.43 KB
Definite time overvoltage protection function 1.1 11/01/2017 790.75 KB
Definite time overvoltage protection function for railway application(ANSI:59; IEC:U>>, U>) 1.0 05/06/2015 485.19 KB
Definite time undervoltage protection function 1.1 11/01/2017 792.96 KB
Definite time undervoltage protection function for railway application(ANSI:27; IEC:U<<, U<) 1.0 25/06/2015 485.40 KB
Directional overpower protection function 1.0 23/04/2012 269.12 KB
Directional residual delayed overcurrent protection function 1.2 25/04/2016 635.23 KB
Directional three-phase time overcurrent protection function 1.2 25/04/2016 574.32 KB
Directional underpower protection function 1.0 23/04/2012 270.29 KB
Disconnector control function block 1.0 27/06/2011 484.00 KB
Distance protection function 1.0 27/06/2011 571.00 KB
Distance protection function for compensated or isolated networks 1.0 27/06/2011 638.23 KB
Distance protection function for railway application(ANSI:21; IEC:Z<) 1.0 05/06/2015 564.99 KB
Distributed busbar differential protection function and breaker failure protection 1.1 30/09/2016 970.48 KB
Disturbance recorder function 3.0 02/06/2017 561.86 KB
Earth fault locator function (ANSI:21N; IEC:Zo<) 1.0 04/11/2019
474.41 KB
Generator differential protection function(ANSI:87G/M) 1.2 08/07/2015 596.48 KB
Impedance protection compounded function 1.0 04/10/2012 541.47 KB
Inrush current detection function 1.0 21/10/2011 453.54 KB
Line differential protection function with transformer 1.0 21/04/2012 562.94 KB
Line measurement function block 1.0 23/03/2012 533.64 KB
Line thermal protection function 1.0 27/06/2011 480.93 KB
Line thermal protection function for railway application(ANSI:49; IEC:T>) 1.0 05/06/2015 584.76 KB
Loss of excitation protection function (version 40Z)(ANSI:40Z) 1.1 21/04/2016 644.81 KB
Loss-of-load (undercurrent) protection function 1.0 21/04/2012 508.20 KB
Metering function 1.1 21/04/2016 573.18 KB
Motor startup supervision function 1.0 08/01/2014 261.02 KB
Motor thermal protection function 1.0 21/02/2012 492.80 KB
Negative sequence overcurrent protection function 1.0 11/02/2014 273.31 KB
Overcurrent protection function for railway application(ANSI:51; IEC:I>>, I>) 1.0 05/06/2015 586.91 KB
Overexcitation protection function 1.0 26/08/2011 491.59 KB
Phase-selective trip logic function(ANSI:94) 1.1 29/05/2017 751.06 KB
Pole discordance detection function 1.0 21/02/2012 465.17 KB
Pole slipping protection function 1.0 20/01/2012 482.75 KB
Residual definite time overcurrent protection function 1.1 31/08/2016 674.66 KB
Residual definite time overvoltage protection function 1.0 18/06/2011 444.39 KB
Residual delayed overcurrent protection function 1.1 31/08/2016 734.82 KB
Residual instantaneous overcurrent protection function 1.0 26/08/2011 442.40 KB
Restricted earth-fault protection function 1.0 27/06/2011 458.61 KB
Simplified trip logic function 1.1 29/05/2017 728.58 KB
Stub protection function 1.0 12/03/2012 502.12 KB
Switch onto fault preparation function 1.0 29/02/2012 476.36 KB
Synchro check synchro switch function 1.0 27/06/2011 506.31 KB
Teleprotection function 1.0 18/07/2011 508.61 KB
Three-phase definite time overcurrent protection function(ANSI:51D; IEC:I>>, I>) 1.1 31/08/2016 743.75 KB
Three-phase instantaneous overcurrent protection function 1.0 26/08/2011 446.25 KB
Three-phase time overcurrent protection function 1.1 31/08/2016 733.60 KB
TRIM Inrush current minimizer function 1.0 06/06/2012 567.84 KB
Voltage input function 1.0 31/01/2012 483.68 KB
Voltage input function for railway application 1.0 05/06/2015 537.80 KB
Voltage transformer and dead line detection supervision function 1.0 25/10/2011 469.58 KB
Function blocks detailed Verzió Formátum Dátum Méret
AIC current input function 1.0 03/01/2017 716.88 KB
Automatic generator synchronizer function 1.0 21/12/2016 758.05 KB
Automatic reclosing function for high voltage networks 1.2 08/02/2017 829.90 KB
Automatic reclosing function for medium voltage networks 1.2 08/02/2017 816.51 KB
Automatic tap changer controller for parallel transformers 1.2 29/01/2013 362.42 KB
Automatic tap changer controller function (ANSI:90V) 1.2 29/01/2013 355.69 KB
Average and maximum measurement function 1.0 27/09/2013 485.80 KB
Breaker failure protection for not solidly grounded networks function 1.0 29/04/2014 194.67 KB
Breaker failure protection for solidly grounded networks function(ANSI:50BF; IEC:CBFP) 1.1 29/04/2014 204.30 KB
Capacitor overvoltage protection function 1.1 30/05/2018 892.68 KB
Capacitor unbalance protection for blocks in bridge connection function 1.1 17/12/2015 867.15 KB
Capacitor unbalance protection for blocks in double delta connection 1.0 01/06/2015 398.98 KB
Capacitor unbalance protection for blocks in double star connection (Version ”U”) function 1.1 20/06/2014 432.97 KB
Capacitor unbalance protection for blocks in double star connection function 1.1 03/12/2012 341.34 KB
Centralized busbar differential and breaker failure protection function (ANSI:87B; IEC:3IdB) 1.0 24/09/2012 1.57 MB
Charging current compensation in line differential protection function 1.0 28/02/2014 236.00 KB
Circuit breaker control function 2.0 01/04/2019 496.29 KB
Circuit breaker control function (single-phase version) 1.0 01/04/2019 563.58 KB
Circuit breaker wear monitoring for railway application function 1.1 06/09/2016 633.81 KB
Circuit breaker wear monitoring function 1.1 06/09/2016 827.78 KB
Current input for railway application function 1.0 19/05/2015 256.87 KB
Current input function 1.0 31/01/2012 463.38 KB
Current transformer supervision function 1.0 18/07/2011 438.02 KB
Current unbalance function(ANSI:60) 1.0 27/06/2011 440.16 KB
Dead line detection function 1.0 27/06/2011 455.06 KB
Definite time overvoltage protection for railway application function (ANSI:59; IEC:U>>, U>) 1.0 29/05/2015 276.66 KB
Definite time overvoltage protection function 1.2 11/01/2017 769.29 KB
Definite time undervoltage protection function 1.1 11/01/2017 764.78 KB
Differential protection function 2.1 19/10/2018 1.10 MB
Directional overpower protection function 1.0 23/04/2012 301.92 KB
Directional residual time overcurrent protection function 1.2 25/04/2016 834.27 KB
Directional residual wattmetric earth-fault protection function 1.0 11/02/2014 349.26 KB
Directional three-phase overcurrent protection function 1.1 25/04/2016 666.39 KB
Directional underpower protection function 1.0 23/04/2012 303.14 KB
Disconnector control function 2.0 01/04/2019 487.06 KB
Distance protection for compensated or isolated networks function(ANSI:21; IEC:Z<) 1.1 13/07/2015 456.86 KB
Distance protection for railway application function (ANSI:21; IEC:Z<) 1.0 29/05/2015 341.01 KB
Distance protection function(ANSI:21; IEC:Z<) 1.2 05/06/2013 495.32 KB
Distance protection with MHO characteristics function(ANSI:21) 1.0 02/08/2012 495.22 KB
Distributed busbar differential and breaker failure protection for resistor grounded networks 1.1 21/11/2016 1.38 MB
Distributed busbar differential and breaker failure protection function 1.1 30/09/2016 1.29 MB
Disturbance recorder function(ANSI:DFR; IEC:DR) 3.0 02/06/2017 707.61 KB
DRL - Petersen Coil Controller function block description 2.2 21/02/2018 719.62 KB
Earth-fault phase selection function 1.0 05/06/2015 262.30 KB
Ethernet links function 1.0 19/02/2019 394.52 KB
Four-channel control function 1.0 06/02/2013 267.73 KB
Generator differential protection function 1.2 08/06/2015 694.15 KB
Generator inadvertent energizing protection function 1.2 26/08/2015 553.35 KB
GGIOmA current measurement function 1.0 03/01/2017 968.24 KB
GGIORTD temperature measurement function 1.1 09/01/2017 971.49 KB
High Speed Bus Transfer 1.0 30/06/2016 821.06 KB
Impedance protection with compounded circular characteristic function 1.0 04/10/2012 810.97 KB
Inrush current detection function 1.0 26/08/2011 414.91 KB
Interturn fault protection function (split phase/current based) 1.0 13/02/2017 796.51 KB
Line differential protection function 1.1 26/10/2018 0.98 MB
Line differential protection with transformer in the protected zone function 1.1 21/03/2013 920.14 KB
Line measurement function 1.0 23/03/2012 546.46 KB
Line thermal protection for railway application function(ANSI:49; IEC:T>) 1.0 13/05/2015 318.18 KB
Line thermal protection function 1.0 25/10/2011 533.04 KB
Lockout Trip Logic function(ANSI:86/94) 1.0 28/02/2019 420.24 KB
Loss of excitation protection function (Version 40Q) 1.3 20/04/2016 720.58 KB
Loss of excitation protection function (Version 40Z) 1.1 21/04/2016 758.44 KB
Loss-of-load protection function 1.0 29/03/2012 253.64 KB
Metering function 1.1 21/04/2016 557.04 KB
Minimum current condition function 1.0 22/09/2015 510.00 KB
Motor startup supervision function(ANSI:48) 1.1 08/01/2014 257.61 KB
Motor thermal protection function(ANSI:49; IEC:T>) 1.0 25/10/2011 537.33 KB
Negative sequence definite time overvoltage protection function 1.0 26/08/2014 195.90 KB
Negative sequence overcurrent protection for generators function 1.1 07/07/2014 211.71 KB
Negative sequence overcurrent protection function 1.2 11/02/2011 262.87 KB
Overcurrent protection for railway application function (ANSI:51; IEC:I>>, I>) 1.0 29/05/2015 297.67 KB
Overexcitation protection function 1.0 27/06/2011 486.72 KB
Overfrequency protection function 2.0 05/06/2019 431.28 KB
Phase-selective trip logic function block description(ANSI:94) 2.0 12/03/2019 540.03 KB
Pole discordance detection function (ANSI:52) 1.0 27/06/2011 446.67 KB
Pole slipping protection function 1.0 25/10/2011 523.45 KB
Rate of change of frequency function 2.0 05/06/2019 414.46 KB
Remote Binary Communication function 1.0 06/02/2013 253.76 KB
Reset control function 1.0 28/02/2014 408.15 KB
Residual definite time overcurrent protection function (ANSI:51ND; IEC:Io>>, Io>) 1.1 31/08/2016 675.08 KB
Residual definite time overvoltage protection function 1.0 27/06/2011 434.06 KB
Residual instantaneous overcurrent protection function 1.0 26/08/2011 441.56 KB
Residual overcurrent protection function 1.2 31/08/2016 712.61 KB
Restricted earth-fault protection function 1.0 27/06/2011 500.66 KB
Rotor earth fault function and hardware description 1.0 28/06/2017 0.96 MB
RTD temperature input function 1.0 03/01/2017 748.71 KB
Sag and swell detection function 1.0 27/06/2011 505.76 KB
Simplified trip logic function(ANSI:94) 2.0 28/02/2019 399.03 KB
Single-pole Trip Logic function with general start reporting(ANSI:94) 1.0 12/03/2019 487.54 KB
Stub protection function 1.0 12/03/2012 252.15 KB
Switch-onto-fault preparation function 1.0 29/02/2012 263.53 KB
Synchro check synchro switch function 1.0 27/06/2011 614.33 KB
Teleprotection function 1.0 18/07/2011 531.17 KB
Third harmonic differential overvoltage protection function 1.1 07/07/2014 383.97 KB
Third harmonic undervoltage protection function 1.0 17/01/2013 262.01 KB
Three-phase definite time overcurrent protection function(ANSI:51D; IEC:I>>, I>) 1.1 31/08/2016 695.24 KB
Three-phase instantaneous overcurrent protection function 1.0 26/08/2011 445.81 KB
Three-phase time overcurrent protection function 1.2 31/08/2016 790.57 KB
Three-pole Trip Logic function with general start reporting(ANSI:94) 1.0 01/03/2019 400.79 KB
Transient earth fault protection function 1.3 27/04/2017 366.84 KB
TRIM Inrush current minimizer function 1.0 29/05/2012 282.46 KB
Trip value recorder function 1.1 16/11/2016 590.28 KB
Underfrequency protection function 2.0 05/06/2019 422.93 KB
Vector jump protection function 1.0 17/01/2013 273.08 KB
Voltage dependent overcurrent protection function 1.0 17/01/2013 269.37 KB
Voltage input for railway application function 1.0 19/05/2015 260.76 KB
Voltage input function 1.0 31/01/2012 472.63 KB
Voltage measurement selection function 1.0 06/02/2013 245.76 KB
Voltage transformer supervision and dead line detection function 1.1 25/10/2011 545.44 KB
Weak end infeed logic function 1.0 29/01/2014 191.10 KB
´Common´ function 1.0 18/01/2014 253.52 KB
´GGIO´ function 1.1 25/04/2016 589.70 KB
Setting guide of the functions Verzió Formátum Dátum Méret
Application guide to the differential protection and restricted earth-fault protection functions for autotransformers 1.1 19/05/2016 0.99 MB
Automatic reclosing function for high voltage networks setting guide(ANSI:79; IEC:0->1) 1.0 20/04/2017 1.41 MB
Automatic reclosing function for medium voltage networks setting guide(ANSI:79; IEC:0->1) 1.0 20/04/2017 1.41 MB
Commissioning guide to the DRL device 1.2 26/02/2018 480.93 KB
Current input function setting guide 1.0 29/01/2015 310.88 KB
Differential protection function setting guide(ANSI:87T; IEC:3IdT) 1.0 19/11/2015 628.86 KB
Directional residual delayed overcurrent protection function setting guide(ANSI:67N; IEC:IoDir>>, IoDir>) 1.0 22/10/2014 354.06 KB
Directional three-phase time overcurrent protection function setting guide(ANSI:67; IEC:IDir>>, IDir>) 1.0 21/10/2014 315.34 KB
Distance protection function setting guide(ANSI:21; IEC:Z<) 1.0 12/06/2015 0.98 MB
High impedance differential protection technical guide 2.0 09/03/2018 2.33 MB
High impedance differential protection technical guide (MS Excel file) 2.0 09/03/2018 150.50 KB
Loss of excitation protection (Version 40Q) function setting guide (ANSI:40Q) 1.0 10/03/2015 319.45 KB
Primary measurement 1.0 24/10/2016 868.37 KB
Third harmonic differential overvoltage protection function(ANSI:59TD; IEC:U3d>) 1.0 08/05/2015 968.29 KB
Transient earth fault protection function 1.2 02/06/2017 1.22 MB
Voltage dependent overcurrent protection function (ANSI:51V; IEC:I> U<) 1.0 18/03/2015 313.31 KB
Voltage input function setting guide 1.0 29/01/2015 363.64 KB
Theoretical descriptions Verzió Formátum Dátum Méret
Numerical transformer inrush current minimizer - Principle of the operation 1.0 28/04/2016 721.66 KB
Power Swing detection(ANSI:68) 1.1 27/09/2013 1.20 MB
Thermal differential equation theory description 1.0 11/11/2010 795.93 KB
Software

A serial number is required to use the EuroCAP configuration tool for EuroProt+ devices.
Please contact the Protecta support team via the Technical support interface for a serial number.

Configuration software Verzió Formátum Dátum Méret
EuroCAP configuration tool (password: PROTECTA) 2.2.1.5 26/03/2018 3.41 MB
Software Guides Verzió Formátum Dátum Méret
EuroCAP configuration tool for EuroProt+ devices 2.7 24/08/2016 4.94 MB
Factory configured macros for the user logic 1.0 16/04/2012 752.46 KB
Release notes Verzió Formátum Dátum Méret
Release and revision history for EuroCAP configuration tool 26/03/2018 701.39 KB
Release and revision history for EuroProt+ firmware 06/08/2019 600.92 KB
Protection function testing Verzió Formátum Dátum Méret
Distance protection (ANSI:21; IEC:Z<) 1.0 14/03/2019 175.36 KB
Line differential protection with transformer (ANSI:87LT; IEC:3IdLT) 1.8 14/03/2019 61.60 KB
Residual overcurrent protection (ANSI:51N, 67N; IEC:IO>>, IO>, IODIR>>, IODIR>) 2.3 14/03/2019 75.65 KB
Three-phase overcurrent protection (ANSI:51, 67; IEC:I>>, I>, IDIR>>, IDIR>) 2.5 14/03/2019 65.12 KB
Transformer and line differential protection (ANSI:87T, 87L; IEC:3IdT, 3IdL) 1.7 14/03/2019 94.83 KB

The latest firmware...

...CDSP: 2.8.13.1550-H2

...RDSP: 2.8.13.2060-H2

SHA-256 hash values of firmware
RDSP versions SHA-256
2.8.13.2060-H2 77c74446332d
2.8.13.2060-H1 0883127b5a72
2.8.13.2060 f3c8fbfcc767
2.8.13.2052-H1 24e013a21037
2.8.13.2051 62ce545febe1
2.8.13.2050-H3 708f55b4ee2f
2.8.13.2050-H2 83b559ebc3cb
2.8.13.2050-H1 bbede90091eb
2.8.13.2050 096405f95a23
2.8.13.2046 2d6a8e5469fb
2.8.13.2045 4e5a12061d18
2.8.13.2044 6480628f8f57
2.8.13.2043-H1 26d3e0537a35
2.8.13.2043 7e34dd2b9dfd
2.8.13.2042 0c4c239635ee
2.8.13.2041-H1 568d49f2c42d
2.8.13.2041 44af05bbfc05
2.8.13.2040-H1 3fc88fb035d7
2.8.13.2040 6b45b18a1523
CDSP versions SHA-256
2.8.13.1550-H2 7ab9664c437b
2.8.13.1550-H1 a97ee0ab7c9f
2.8.13.1550 2a57877e836b
2.8.13.1540-H1 85cb3829967f
2.8.13.1540 9d8305f6817c
2.8.13.1530-H1 2d2db63e7933
2.8.13.1530 d445f0cb02af
2.8.13.1522 555406576856
2.8.13.1521 3a5518d74fd0
2.8.13.1520-H1 b0e92a4064be
2.8.13.1520 38ccc976b051
2.8.13.1510 ddb90136bbf6
This website uses cookies. By further use of this site you agree to these cookies being set. Learn more...