Directional 3Ph+Io overcurrent, over- undervoltage, frequency protection & autorecloser
Directional 3Ph+Io overcurrent, over- undervoltage, frequency protection & autorecloser
Directional 3Ph+Io overcurrent, over- undervoltage, frequency protection & autorecloser
Directional 3Ph+Io overcurrent, over- undervoltage, frequency protection & autorecloser
The E3-Feeder is a dedicated feeder protection and control IED; it is member of the DTIVA product type in the EuroProt+ product family.
The DTIVA products are configured to protect, control and supervise elements of the utility and industrial distribution systems, including radial, looped and meshed distribution networks. Because of the modular architecture, the modules are assembled and configured according to the user’s requirements; from that point on, the software determines the functions.
The main areas of application are the not solidly grounded radial networks. Here the application of Petersen coils or grounding resistances results relatively low currents in case of single phase-to-ground faults. The majority of the protections are based on current measurements only, but the application of distributed generation or loops in the network topology require additional voltage measurement and directional protection functions. The distance and line differential protections are also available to protect compensated or isolated networks.
The EuroCAP configuration tool, which is available free of charge, offers a user-friendly and flexible application for protection, control and measurement functions to ensure that the IED-EP+ devices are fully customisable.
The E3-Feeder relay is designed to meet the requirements of a complex field unit for overhead lines and cables on compensated or resistance grounded networks.
The range of functions includes all current- and voltage-based applications: directional overcurrent and directional earth-fault protection, power calculation and over- and undervoltage. Frequency protection functions are also included.
All the functions necessary for switchgear control and monitoring are included in the E3-Feeder relay. The automatic reclosing function is performed with synchrocheck.
The relay can also be used for circuit-breaker failure protection.
The E3-Feeder configuration measures three phase currents, the residual current and, additionally, three phase voltages and the busbar voltage. These measurements allow, in addition to the current- and voltage-based functions, directionality extension of the configured phase and residual overcurrent functions and also directional overpower or underpower functions. It is intended to protect overhead line or cable networks. The range of functions is supplemented with the automatic reclosing function and synchro-check. Based on the voltage measurement, the frequency is evaluated to realize frequency-based protection functions.

| Protection & control functions | IEC | ANSI | *Inst. | |||
|---|---|---|---|---|---|---|
| Directional Element function (2.10 systems only) | ? | ? | 1 | 2025.07.11. | download | |
| Synchro check synchro switch function | SYNC | 25 | 1 | 2024.11.14. | download | |
| Definite time undervoltage protection function | U<, U<< | 27 | 2 | 2024.12.19. | download | |
| Directional overpower protection function | P> | 32 | 1 | 2024.12.20. | download | |
| Directional underpower protection function | P< | 37 | 1 | 2024.12.20. | download | |
| Negative sequence overcurrent protection function | I2> | 46 | 1 | 2025.04.04. | download | |
| Broken conductor protection | I2/I1> | 46BC | 1 | 2020.06.30. | download | |
| Negative sequence definite time overvoltage protection function | U2 > | 47 | 1 | 2024.10.10. | download | |
| Line thermal protection function | T > | 49 | 1 | 2025.01.03. | download | |
| Three-phase instantaneous overcurrent protection function | I >>> | 50 | 1 | 2025.01.17. | download | |
| Residual instantaneous overcurrent protection function | Io>>> | 50N/50G | 1 | 2025.12.09. | download | |
| Breaker failure protection functions | CBFP | 50BF | 1 | 2022.10.03. | download | |
| Three-phase time overcurrent protection function | I>, I>> | 51 | 2 | 2025.04.04. | download | |
| Residual overcurrent protection function | Io>, Io>> | 51N/51G | 2 | 2025.04.04. | download | |
| Definite time overvoltage protection function | U>, U>> | 59 | 2 | 2024.12.19. | download | |
| Residual definite time overvoltage protection function | Uo>, Uo>> | 59N | 2 | 2024.12.20. | download | |
| Current unbalance function (CT Supervision) | 60 | 1 | 2024.12.20. | download | ||
| Directional three-phase overcurrent protection function | I Dir>, I Dir>> | 67 | 2 | 2025.04.04. | download | |
| Directional residual time overcurrent protection function | Io Dir>, Io Dir>> | 67N/67G | 2 | 2025.12.03. | download | |
| Inrush current detection function | I2h> | 68 | 1 | 2024.12.20. | download | |
| Automatic reclosing function for medium voltage networks | 0 -> 1 | 79 | 1 | 2024.12.10. | download | |
| Overfrequency protection function | f>, f>> | 81O | 2 | 2024.12.20. | download | |
| Underfrequency protection function | f<, f<< | 81U | 2 | 2024.12.20. | download | |
| Rate of change of frequency function | df/dt | 81R | 2 | 2024.12.20. | download |
| IEC61850 documents | |||
|---|---|---|---|
| TISSUEs Implementation Conformance Statement (TICS) for the IEC 61850 Edition 2 server interface in Europrot+ product family | 18/04/2023 | download | |
| Protocol Implementation eXtra Information for Testing (PIXIT) for the IEC 61850 Edition 2 server interface in Europrot+ product family | 18/04/2023 | download | |
| Protocol Implementation Conformance Statement (PICS) for the IEC 61850 Edition 2 server interface in Europrot+ product family | 18/04/2023 | download | |
| Model Implementation Conformance Statement (MICS) for the IEC 61850 Edition 2 server interface in DTIVA product | 18/04/2023 | download | |
| Model Implementation Conformance Statement (MICS) for the IEC 61850 Edition 1 server interface in the Eurorot+ product family | 21/05/2012 | download | |
| Protocol Implementation Conformance Statement (PICS) for the IEC 61850 Edition 1 server interface in Eurorot+ product family | 20/03/2017 | download | |
| Protocol Implementation eXtra Information for Testing (PIXIT) for the IEC 61850 Edition 1 server interface in Europrot+ product family | 20/03/2017 | download | |
| Type description | |||
| Distributed network components protection & control | 18/07/2025 | download | |
| Hardware Guides | |||
| Hardware description | 05/05/2025 | download | |
| Maintenance guide | 28/06/2023 | download | |
| Application Guides | |||
| Operating Manual and Troubleshooting Guide - system version: 2.8 | 19/09/2023 | download | |
| Configuration Descriptions | |||
| E3-Feeder configuration description | 19/06/2014 | download | |
| E3-Feeder_H product configuration options | 25/02/2026 | download | |
| E3-Feeder_F product configuration options | 25/02/2026 | download |