Login registration
e-mail Password Forgot Your password?
Please enter the email address you provided during your previous registration, to which we will send your tasks!
full name e-mail alternate e-mail language Password confirm password company position mailing address Phone number

E9-Feeder

Vectorjump, over- and underpower and frequency protection

E9-Feeder

Vectorjump, over- and underpower and frequency protection

E9-Feeder

Vectorjump, over- and underpower and frequency protection

E9-Feeder

Vectorjump, over- and underpower and frequency protection

Protection & control functions

Protection & control functions IEC ANSI *Inst.
Definite time undervoltage protection function U<, U<< 27 2 2024.12.19. download
Directional overpower protection function P> 32 1 2024.12.20. download
Directional underpower protection function P< 37 1 2024.12.20. download
Broken conductor protection I2/I1> 46BC 1 2020.06.30. download
Breaker failure protection functions CBFP 50BF 1 2022.10.03. download
Three-phase time overcurrent protection function I>, I>> 51 2 2025.04.04. download
Residual overcurrent protection function Io>, Io>> 51N/51G 2 2025.04.04. download
Definite time overvoltage protection function U>, U>> 59 2 2024.12.19. download
Residual definite time overvoltage protection function Uo>, Uo>> 59N 2 2024.12.20. download
Current unbalance function (CT Supervision) 60 1 2024.12.20. download
Overfrequency protection function f>, f>> 81O 2 2024.12.20. download
Underfrequency protection function f<, f<< 81U 2 2024.12.20. download
Rate of change of frequency function df/dt 81R 2 2024.12.20. download
Vector jump protection function ΔφU> 78VJ 1 2019.07.09. download
*The INST. column contains the numbers of the pre-configured function blocks in the factory configuration.These numbers may be different in order to meet the user’s requirements.

Documentation

Product Configuration Options
IEC61850 documents
TISSUEs Implementation Conformance Statement (TICS) for the IEC 61850 Edition 2 server interface in Europrot+ product family 18/04/2023 download
Protocol Implementation eXtra Information for Testing (PIXIT) for the IEC 61850 Edition 2 server interface in Europrot+ product family 18/04/2023 download
Protocol Implementation Conformance Statement (PICS) for the IEC 61850 Edition 2 server interface in Europrot+ product family 18/04/2023 download
Model Implementation Conformance Statement (MICS) for the IEC 61850 Edition 2 server interface in DTIVA product 18/04/2023 download
Model Implementation Conformance Statement (MICS) for the IEC 61850 Edition 1 server interface in the Eurorot+ product family 21/05/2012 download
Protocol Implementation Conformance Statement (PICS) for the IEC 61850 Edition 1 server interface in Eurorot+ product family 20/03/2017 download
Protocol Implementation eXtra Information for Testing (PIXIT) for the IEC 61850 Edition 1 server interface in Europrot+ product family 20/03/2017 download
Type description
Distributed network components protection & control 18/07/2025 download
Hardware Guides
Hardware description 05/05/2025 download
Maintenance guide 28/06/2023 download
Application Guides
Operating Manual and Troubleshooting Guide - system version: 2.8 19/09/2023 download
Configuration Descriptions
E9-Feeder_H product configuration options 06/01/2026 download

Order

Protecta products can be ordered by using an Order Code. This code specifies the hardware and the configuration.
Please always refer to a valid Order Code when placing an order.
The Order Code page can be opened by clicking the link below.